NEMA Watertight Hubbell Twist-Lock System | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Rating | IP66 Suitability | |||||||||
Configuration Male/Female |
Voltage | Amperage | Wires | Poles | Plug | Inlet | Connector | Receptacle | Adapter | |
NEMA L5-20 |
125V AC | 20 amps | 3 Wires | 2 Poles | HBL2311SW | HBL2315SW | HBL2313SW | HBL2310SW | Custom | |
NEMA L6-20 |
250V AC | 20 amps | 3 Wires | 2 Poles | HBL2321SW | HBL2325SW | HBL2323SW | HBL2320SW | Custom | |
NEMA L7-20 |
277V AC | 20 amps | 3 Wires | 2 Poles | HBL2331SW | HBL2335SW | HBL2333SW | HBL2330SW | Custom | |
NEMA L14-20 |
125/250V AC | 20 amps | 4 Wires | 3 Poles | HBL2411SW | HBL2415SW | HBL2413SW | HBL2410SW | Custom | |
NEMA L15-20 |
3Ø 250V AC | 20 amps | 4 Wires | 3 Poles | HBL2421SW | HBL2425SW | HBL2423SW | HBL2420SW | Custom | |
NEMA L16-20 |
3Ø 480V AC | 20 amps | 4 Wires | 3 Poles | HBL2431SW | HBL2435SW | HBL2433SW | HBL2430SW | Custom | |
NEMA L21-20 |
3ØY 120/208V AC | 20 amps | 4 Wires | 4 Poles | HBL2511SW | - | HBL2513SW | HBL2510SW | Custom | |
NEMA L5-30 |
125V AC | 30 amps | 3 Wires | 2 Poles | HBL2611SW | HBL2615SW | HBL2613SW | HBL2610SW | Custom | |
NEMA L6-30 |
250V AC | 30 amps | 3 Wires | 2 Poles | HBL2621SW | HBL2625SW | HBL2623SW | HBL2620SW | Custom | |
NEMA L14-30 |
125/250V AC | 30 amps | 4 Wires | 3 Poles | HBL2711SW | HBL2715SW | HBL2713SW | HBL2710SW | Custom | |
NEMA L15-30 |
3Ø 250V AC | 30 amps | 4 Wires | 3 Poles | HBL2721SW | HBL2725SW | HBL2723SW | HBL2720SW | Custom | |
NEMA L16-30 |
3Ø 480V AC | 30 amps | 4 Wires | 3 Poles | HBL2731SW | HBL2735SW | HBL2733SW | HBL2730SW | Custom | |
NEMA L17-30 |
3Ø 600V AC | 30 amps | 4 Wires | 3 Poles | HBL2741SW | HBL2745SW | HBL2743SW | HBL2740SW | Custom | |
NEMA L21-30 |
3ØY 120/208V AC | 30 amps | 4 Wires | 4 Poles | HBL2811SW | HBL2815SW | HBL2813SW | HBL2810SW | Custom |
NEMA Enclosure Type Number | Basic Description |
---|---|
1 | Indoor enclosures which protect personnel from incidental contact and also protect against falling dirt. |
2 | Indoor enclosures which protect personnel from incidental contact, protect against falling dirt, and protect against dripping and light splashing of non-corrosive liquids. |
3 | Indoor/outdoor enclosures which protect personnel from incidental contact, protect against falling dirt, rain, sleet, snow, and windblown dust and protect against external ice. |
3R | Indoor/outdoor enclosures which protect personnel from incidental contact, protect against falling dirt, rain, sleet, and snow, and protect against external ice. |
3S | Indoor/outdoor enclosures which protect personnel from incidental contact, protect against falling dirt, rain, sleet, snow, and windblown dust and protects external mechanisms from ice. |
4 | Indoor/outdoor enclosures which protect personnel from incidental contact, protect against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water and protect against external ice. |
4X | Indoor/outdoor enclosures which protect personnel from incidental contact, protect against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, and corrosion and protect against external ice. |
5 | Indoor/outdoor enclosures which protect personnel from incidental contact, protect against falling dirt, settling airborne dust, lint, fibers, and flyings, and protect against dripping and light splashing of non-corrosive liquids. |
6 | Indoor/outdoor enclosures which protect personnel from incidental contact, protect against falling dirt, rain, sleet, snow, hose-directed water and temporary submersion at a limited depth, and protect against external ice. |
6P | Indoor/outdoor enclosures which protect personnel from incidental contact, protect against falling dirt, rain, sleet, snow, hose-directed water, corrosion, and prolonged submersion at a limited depth, and protect against external ice. |
7 | Indoor enclosures for use in hazardous locations classified as Class I, Division 1, Groups A, B, C, or D as defined in NFPA 70. |
8 | Indoor/outdoor Enclosures for use in hazardous (Classified) locations classified as Class I, Division 1, Groups A, B, C, and D as defined in NFPA 70. |
9 | Indoor enclosures for use in hazardous locations classified as Class II, Division 1, Groups E, F, or G as defined in NFPA 70. |
10 | Enclosures that meet the Mine Safety and Hestyle="width: 90px; height: auto" alth Administration requirements, 30 CFR, Part 18. |
12 | Indoor enclosures without knockouts which protect personnel from incidental contact, protect against falling dirt, circulating dust, lint, fibers, and flyings, dripping and light splashing of non-corrosive liquids, and light splashing and seepage of oil and non-corrosive coolants. |
12K | Indoor enclosures with knockouts which protect personnel from incidental contact, protect against falling dirt, circulating dust, lint, fibers, and flyings, dripping and light splashing of non-corrosive liquids, and light splashing and seepage of oil and non-corrosive coolants. |
13 | Indoor enclosures which protect personnel from incidental contact, protect against falling dirt, circulating dust, lint, fibers, and flyings, and spraying, splashing, and seepage of water, oil, and non-corrosive coolants. |
*NEMA ratings provide "a degree of protection" (not absolute protection).
Ingress Protection (IP) Rating | |||
---|---|---|---|
IP Number | First Digit - Protection from Solids | IP Number | Second Digit - Protection from Liquids |
0 | Not protected from solids. | 0 | Not protected from liquids. |
1 | Protected against solid objects over 50 mm, e.g. accidental touch by persons hands. | 1 | Protection against vertically falling drops of water e.g. condensation. |
2 | Protected against solid objects over 12 mm, e.g. persons fingers. | 2 | Protection against direct sprays of water up to 15° from the vertical. |
3 | Protected against solid objects over 2.5 mm (tools and wires). | 3 | Protected against direct sprays of water up to 60° from the vertical. |
4 | Protected against solid objects over 1 mm (tools, wires, and small wires). | 4 | Protection against water sprayed from all directions - limited ingress permitted. |
5 | Protected against dust limited ingress (no harmful deposit). | 5 | Protected against low pressure jets of water from all directions - limited ingress. |
6 | Totally protected against dust ingress. | 6 | Protected against temporary flooding of water, e.g. for use on ship decks - limited ingress permitted. |
7 | – | 7 | Protected against the effect of immersion between 15 cm and 1 M. |
8 | – | 8 | Protects against long periods of immersion under pressure. |
9k | – | 9k | Protected against close range high pressure, high temperature water jet. |
Popular IP Ratings | ||||||||
---|---|---|---|---|---|---|---|---|
IP Code | First Digit - Protection from Solids | Second Digit - Protection from Liquids | ||||||
IP10 | Protected against solid objects over 50 mm, e.g. accidental touch by persons hands. | Not protected from liquids. | ||||||
IP11 | Protected against solid objects over 50 mm, e.g. accidental touch by persons hands. | Protection against vertically falling drops of water e.g. condensation. | ||||||
IP14 | Protected against solid objects over 50 mm, e.g. accidental touch by persons hands. | Protection against water sprayed from all directions - limited ingress permitted. | ||||||
IP20 | Protected against solid objects over 12 mm, e.g. persons fingers. | Not protected from liquids. | ||||||
IP44 | Protected against solid objects over 1 mm (tools, wires, and small wires). | Protection against water sprayed from all directions - limited ingress permitted. | ||||||
IP52 | Protected against dust limited ingress (no harmful deposit). | Protection against direct sprays of water up to 15° from the vertical. | ||||||
IP54 | Protected against dust limited ingress (no harmful deposit). | Protection against water sprayed from all directions - limited ingress permitted. | ||||||
IP55 | Protected against dust limited ingress (no harmful deposit). | Protected against low pressure jets of water from all directions - limited ingress. | ||||||
IP56 | Protected against dust limited ingress (no harmful deposit). | Protected against temporary flooding of water, e.g. for use on ship decks - limited ingress permitted. | ||||||
IP65 | Totally protected against dust ingress. | Protected against low pressure jets of water from all directions - limited ingress. | ||||||
IP66 | Totally protected against dust ingress. | Protected against temporary flooding of water, e.g. for use on ship decks - limited ingress permitted. | ||||||
IP67 | Totally protected against dust ingress. | Protected against the effect of immersion between 15 cm and 1 M. | ||||||
IP68 | Totally protected against dust ingress. | Protects against long periods of immersion under pressure. |
Conversion of NEMA Type Numbers to IEC Class Designations | ||||
---|---|---|---|---|
NEMA Enclosure Type Number | IEC Enclosure Class Designation | Description | ||
1 | IP10 | General Purpose | ||
2 | IP11 | Drip-proof - Indoor | ||
3 | IP54 | Dust-tight, Rain-tight and Sleet (Ice) Resistant - Outdoor | ||
3R | IP14 | Rainproof and Sleet (Ice) Resistant - Outdoor | ||
3S | IP44, IP54 | Dust-tight, Rain-tight, and Sleet (Ice) Proof - Outdoor | ||
4 | IP56 | Watertight and Dust-tight - Indoor and Outdoor | ||
4X | IP56 | Watertight, Dust-tight and Corrosion-Resistant - Indoor and Outdoor | ||
5 | IP52 | Superseded by Type 12 for Control Apparatus | ||
6 | IP67 | Submersible, Watertight, Dust-tight and Sleet (Ice) Resistant - Indoor and Outdoor | ||
12 | IP52 | Industrial Use, Dust-tight and Drip-tight - Indoor | ||
12K | IP52 | Industrial Use, Dust-tight and Drip-tight with Knockouts - Indoor | ||
13 | IP54 | Oil-tight and Dust-tight - Indoor |